LK3U / ZK3U PLC Program Download Tutorial

This tutorial will introduce how to download programs to Lingkong LK3U / ZK3U PLC using different methods, including serial RS232, serial RS485, and Ethernet download methods. Please choose the appropriate download method based on the actual device and interface.


1. Serial RS232 Download Tutorial

Preparation:

Use a standard USB to RS232 cable.

Install the USB to the RS232 driver. The driver can be obtained from the cable manufacturer.

Confirm the COM port:

After installing the driver, open the Device Manager to view the COM port corresponding to the USB to RS232.

If there are multiple COM ports and you cannot determine the port number corresponding to the USB to RS232, you can unplug the USB to RS232 cable and then check which COM port disappears in the Device Manager. After plugging it back in, confirm that the port number is the USB to RS232 port.

PLC preparation:

Confirm that the PLC is powered on and check whether the indicator lights are normal: the power light is on and the running light is flashing.

Use a USB to RS232 cable to connect the computer and PLC.

Software operation:

Open the PLC programming software.

Perform a communication test. If the first communication test fails, you can try multiple times.

If the PLC is in stop state, confirm that the operation is safe and click Execute Download.


2. Serial RS485 Download Tutorial

Preparation:

Use a standard USB to RS485 cable.

Install the USB to RS485 driver. The driver can be obtained from the cable manufacturer.

Confirm the COM port:

After the driver is installed, open the Device Manager to view the COM port corresponding to the USB to RS485.

If there are multiple COM ports and you cannot determine the port number corresponding to the USB to RS485, you can unplug the USB to RS485 cable and check the COM port that disappears in the Device Manager. After plugging it back in, confirm that the port number is the USB to RS485 port.

PLC preparation:

Confirm that the PLC is powered on and check whether the indicator lights are normal: the power light is on and the running light is flashing.

Use a USB to RS485 cable to connect the computer and PLC, and pay attention to the selection according to the download port:

When using 485-1 to download, connect the positive and negative poles of the A/B of the cable to the 485-1 of the PLC.

When using 485-2 to download, connect the positive and negative poles of the A/B of the cable to the 485-2 of the PLC.

Note: By default, the PLC uses RS485 as the programming port. If the protocol of the RS485 interface is changed to another protocol, the program cannot be downloaded.

Software operation:

Open the PLC programming software.

Perform a communication test. If the communication test fails, you can try multiple times.

If the PLC stops, confirm that the operation is safe and click to execute the download.


3. Ethernet download tutorial

1. Download via Ethernet hub

Connect devices:

Use an Ethernet cable to connect the PLC and computer to the same router or switch.

Configure PLC IP:

Open the Ethernet configuration software and set the PLC IP address, subnet mask and router IP address.

Download Ethernet parameters:

Use the serial port (RS232 or RS485) to download Ethernet parameters to the PLC. After completion, power off and restart the PLC.

Check the network connection:

After the PLC restarts, use the PING command to check whether the set IP address is normal. If it cannot be connected normally, please check the network cable connection.

Program download:

Open the PLC programming software and establish a communication connection. After successful communication, you can write the program or perform monitoring operations.

2. Ethernet direct download

Connecting devices:

Use an Ethernet cable to connect the PLC directly to the computer without going through a router or switch.

Configure the computer:

Configure the computer network so that it is in the same network segment as the PLC’s IP address.

Download steps:

The direct connection download method is the same as the hub connection download method. IP configuration and program download are performed according to the hub download process.


Download common errors

An unusable com port is specified

Solution: Check whether the USB driver com port in the device manager is consistent with the software

A drive name error occurs

Solution

Summary

Lingkong LK3U / ZK3U PLC supports multiple ways of program download, including serial port RS232, RS485 and Ethernet connection. The specific operation process of each download method is slightly different, and the corresponding cable connection and driver installation are required according to the interface type used. After completing the communication test, the program can be downloaded to the PLC to ensure safe operation.